Description
The Lancer Plate and 3-1-1-3 Flex Manifold Assembly for 8 LEV Valve Drop-In is the precision flow-control core responsible for distributing syrup and water to the valve heads. The ‘Flex’ design allows for optimized circuit routing, while the high-pressure block ensures zero cross-contamination between flavor streams.
Problem Solved: Corrects manifold-level syrup seepage and ensures stable, leak-free seat for valve plungers. Prevents ‘flavor carry-over’ where one beverage contaminates another by maintaining distinct internal divider walls.
Symptoms of Failure: Drinks tasting watered-down or overly sweet, constant dripping from the nozzle tip after release, or finding ‘mixed’ syrup flavors at the dispensing head.
Technician’s Note: Verify Brix ratios monthly with a refractometer. Ceramic flow control modules require zero manual adjustment once set but are brittle; handle carefully during manifold swaps. Use food-grade silicone on all port o-rings.Technical Specifications:
- Valve Capacity: 8 LEV Valves
- Manifold Layout: 3-1-1-3 Configuration
- Application: High-Volume Drop-In Service
- Manufacturer: Lancer






Reviews
There are no reviews yet.