Description
The Lancer Coil Assembly Water Volumetric Valve is the precision solenoid and flow module responsible for managing the water portion of the beverage mix. In a volumetric valve, this coil must open and close with millisecond accuracy to ensure the water volume matches the programmed pour size regardless of line surges.
Problem Solved: Corrects inconsistent beverage flavor and prevents syrup waste by providing a positive shut-off and stable flow control. Replaces coils that have developed weak magnetic fields or insulation shorts.
Symptoms of Failure: Drinks tasting watered-down or overly sweet (improper water portion), constant dripping from the nozzle tip after release, or valves that ‘burp’ gas due to incomplete seal closure.
Technician’s Note: Verify Brix ratios with a refractometer after installation. Ceramic flow control modules require zero manual adjustment once set but are brittle; check the water intake filter on the manifold for grit before installing the new coil.Technical Specifications:
- Manufacturer: Lancer
- Valve Series: Volumetric Control
- Application: Chilled Water Flow Management
- Type: Solenoid Coil and Seal Assembly






Reviews
There are no reviews yet.