Description
The Lancer Accumulator .375 Holes for CED is a specialized pressure-damping component designed to absorb hydraulic shocks within the beverage manifold. It acts as a buffer to smooth out pressure spikes from the water pump, ensuring that the carbonated water flow remains steady and laminar during the dispensing cycle.
Symptoms of Failure: If the machine is vibrating or making a ‘thumping’ noise during use, the accumulator is likely restricted or failed. This lack of damping results in excessive foaming at the nozzle and an inconsistent ‘splattering’ splash pattern that makes for an unappealing customer experience.
Technician’s Note: Check the accumulator ports for mineral scale buildup. Hard water deposits can clog the small entry holes, preventing the unit from absorbing pressure shocks. Soaking in a mild delimer can often restore performance.Technical Specifications:
- Manufacturer: Lancer
- Feature: .375″ Damping Holes
- Application: Pressure shock absorption
- Compatibility: CED Counter-Electric Units






Reviews